PATENTS
|
| Orycon products are covered under the following U.S. Patents: |
5,072,078
5,227,179
5,352,109
|
5,503,545
6,746,231
and patents pending |
|
NOZZLES
|
| Thermocouples: Type J |
Heaters: Nominal voltage - 220V AC
Operating Voltage - 196V to 248V |
Material: AISI H-13
AISI 420-SS |
| Fit Diameter Tolerances: |
Head: + 0.003" - 0.000 over nominal dia.
+ 0,07mm - 0,00mm over nominal dia. |
Front Shut-off: + 0.0005" to +0.001" over nominal dia.
+ 0,012mm to + 0,025mm over nominal dia. |
MANIFOLDS
|
| Thermocouples: Type J |
Heaters: Type - Tubular
Nominal voltage - 220V AC
Operating Voltage - 196V to 248V |
Material: AISI H-13
AISI 420-SS |
| Cold Operation: 0.001" - 0.002" (depending on size) |
| 0,02mm - 0,05mm (depending on size) |
VALVE GATES
|
Hydraulic Type:
Max Operating Pressure - 400PSI |
Pneumatic Type:
Max Operating Pressure - 150PSI |
CONTROLLERS
|
1 & 2 Zones:
Operational Voltage - 196V to 248V
Max AMPS per zone - 15 and 30
Thermocouple Types: J, K
Calibration in º F and º C |
Multi-Zone
Operational Voltage -196V to 248V 3 Phase (w/Transformer-440V to 480V 3 phase
Max AMPS per zone - 15 and 30
Thermocouple Types: J, K
Calibration in º F and º C |