STANDARD SPECIFICATIONS

PATENTS
Orycon products are covered under the following U.S. Patents:

5,072,078
5,227,179
5,352,109

5,503,545
6,746,231
and patents pending
NOZZLES
Thermocouples: Type J
Heaters: Nominal voltage -    220V AC
             Operating Voltage - 196V to 248V
Material: AISI H-13
             AISI 420-SS
Fit Diameter Tolerances:
                   Head:   + 0.003" - 0.000 over nominal dia.
                               + 0,07mm - 0,00mm over nominal dia.
       Front Shut-off:   + 0.0005" to +0.001" over nominal dia.
                               + 0,012mm to + 0,025mm over nominal dia.
MANIFOLDS
Thermocouples: Type J
Heaters: Type - Tubular
             Nominal voltage -    220V AC
             Operating Voltage - 196V to 248V
Material: AISI H-13
             AISI 420-SS
Cold Operation: 0.001" - 0.002" (depending on size)
                       0,02mm - 0,05mm (depending on size)
VALVE GATES
Hydraulic Type:
              Max Operating Pressure - 400PSI
Pneumatic Type:
              Max Operating Pressure - 150PSI
CONTROLLERS
1 & 2 Zones:
              Operational Voltage - 196V to 248V
              Max AMPS per zone - 15 and 30
              Thermocouple Types: J, K
              Calibration in º F and º C
Multi-Zone
              Operational Voltage -196V to 248V 3 Phase (w/Transformer-440V to 480V 3 phase
              Max AMPS per zone - 15 and 30
              Thermocouple Types: J, K
              Calibration in º F and º C